Image unavailable
Philips Dreamstation BiPAP ST Noninvasive Ventilator
Sleep and respiratory care line · Philips reference HCINX1030T19
| Modes | CPAP, S, S/T |
|---|---|
| Weight | 1.33 kg without humidifier; 1.98 kg with humidifier, including power supply |
| Filters | Reusable pollen; disposable ultra-fine |
| Voltage | 100 – 240 VAC |
| Amperage | 2.0-1.0 A |
| Frequency | 50/60 Hz |
| Ramp time | 0 (off) to 45 minutes (increment is 5 minutes) |
| Rise time | 1 to 6 (100 to 600 ms) |
| Dimensions | 15.7 x 19.3 x 8.4 cm without humidifier; 29.7 x 19.3 x 8.4 cm with humidifier |
| Regulatory | Philips lists this line as a prescription device and marks it "Not for sale in the United States" |
| Intended use | Philips states: "The BiPAP S/T device is intended to provide non-invasive ventilatory support to treat adult and pediatric (> 7 years of age and > 40 Ibs) patients with obstructive Sleep Apnea (OSA) and Respiratory Impairment. The device may be used in the hospital or home." |
| Product type | Noninvasive ventilator |
| Humidification | Heated humidification: fixed, adaptive |
| Device controls | LCD, control dial/push button |
| Inspiration time | 0.5 to 3.00 seconds (increment is 0.1 seconds) |
| Philips category | Sleep and Respiratory Care — Ventilation — Ventilators |
| Breath per minute | 1 to 30 (increment is 1 breath) |
| Philips part number | HCINX1030T19 |
| Ventilation pressure | 4 to 30 cm H₂O (increment is 0.5 cm H₂O); EPAP: 4 to 25 cm H₂O; CPAP max pressure is 20 cm H₂O |
Philips states of this line: "The BiPAP S/T device is intended to provide non-invasive ventilatory support to treat adult and pediatric (> 7 years of age and > 40 Ibs) patients with obstructive Sleep Apnea (OSA) and Respiratory Impairment. The device may be used in the hospital or home." It runs CPAP, S and S/T modes over a pressure range of 4 to 30 cm H₂O, with heated humidification and an LCD control panel, and weighs 1.33 kg without the humidifier. Philips lists it as a prescription device and marks it "Not for sale in the United States"; the specifications here are taken from the en-US Philips storefront, because philips.ae does not publish a page for this reference. The power supply accepts 100–240 VAC at 50/60 Hz, which matters to a distributor moving stock between regions. Professional medical equipment: supply into the UAE is subject to MOHAP device registration and to the buyer's own facility approvals, and no price is published for this line — ask the sales desk for a quotation.
Availability, quantities, dispatch timing and delivery terms are confirmed in your quotation for the requested destination. Include the product model, quantity and destination in your enquiry.